Place of Origin: | China |
Brand Name: | LUY |
Minimum Order Quantity: | 1 set |
---|---|
Price: | Negotiable |
Packaging Details: | Nude packing, can be shipped by containers or bulk cargo |
Delivery Time: | Shipped in 35 days after received payment |
Payment Terms: | T/T, L/C, D/A, D/P, Western Union, MoneyGram |
Supply Ability: | 5000 set per year |
Material: | Q345R Carbon Steel Or Stainless Steel | Effective Diameter: | 500-4500mm |
---|---|---|---|
Pressure Error: | ±0.01MPA | Vacuum Degree: | -0.098Mpa |
Effective Length: | 1000-20000mm | Delivery Time: | About 35 Days |
High Light: | small composite autoclave,large capacity autoclave |
Pressure And Temperature Customized Composite Autoclave Full Automatic Control
Ⅰ Product description
The computer is fully automatic controlled, the temperature data and pressure data in the tank are collected and transmitted to the computer control box, and the temperature value in the tank is displayed in real time on the touch screen panel. The pressure value is convenient and intuitive. Temperature parameters, pressure parameters, vacuum parameters, time parameters, etc. can be set according to the autonomous requirements of the product.
The autoclave is mainly used for the molding of polymer-based composite component products. It is the main equipment for manufacturing continuous fiber reinforced thermosetting composite materials. It is widely used in the molding of advanced composite materials, honeycomb sandwich structures and metal or composite bonding mechanisms.
Ⅱ Technical parameters
Effective diameter | 500-4500mm |
Effective length | 1000-20000mm |
Operating temperature | 100-450℃ |
Working pressure | 0.5-5.0Mpa |
Speed of pressure rise | 0.05Mpa/min Continuously adjustable |
Pressure error | ±0.01MPA |
Heating rate (no load) | 0.5-7℃/min Continuously adjustable |
Cooling rate (no load) | 0.5-7℃/min Continuously adjustable |
Cooling method | Water cooling or air cooling |
Point temperature error | ±1-2℃ |
Temperature control and temperature measurement points | Inside tank and 2-20point |
Vacuum Degree | -0.098MPA |
Extract Vacuum pipe line | 2-20 |
Test Vacuum pipe line | 2-20 |
Continuous working ability | ≥50 hours |
Ⅲ Details
1. Control system
The control system adopts professional hot-pressure temperature control software, which consists of PLC temperature control module, temperature sensor, pressure sensor, control cabinet and connection line. The PL temperature control module is used to transmit the temperature data in the tank through the temperature sensor to the PLC control cabinet, and the temperature value is displayed on the computer in real time. The insulation phase program automatically calls the PID temperature setting to ensure the accuracy and stability of the temperature inside the autoclave.
2. Vacuum system
The vacuum system consists of vacuum pump, vacuum pumping line, vacuum measuring line, backup buffer tank and vacuum buffer tank. Each vacuum line has pressure sensor, pneumatic valve, manual valve and pressure leak alarm. The vacuum line working relative independence. When one of the vacuum lines fails, this vacuum line can be cut off separately, reducing the impact on the entire vacuum system and ensuring the stability and safety of the vacuum system.
3. Heating system
Using professional hot-press temperature control software, consists of thermocouple, PLC temperature control module power regulator, control cabinet and connection line. The temperature data in the tank is collected by the thermocouple and transmitted to the PLC, and then the output power is adjusted to the heating tube by the PLC and the power regulator. The special 304 stainless steel electric heating tube is heated quickly and has a long service life. The temperature fan circulates and spreads the heat in the tank more uniformly through the special temperature circulation board. The temperature is uniform and there is no dead angle and the pressure is constant.
4. Cooling system
The water cooling method is adopted, and the temperature of each point in the tank collected by the thermocouple is transmitted to the PLC control system. According to the user's process requirements, the control system controls the circulating rate of the variable frequency cooling pump and the circulation rate of the high temperature and high pressure fan, thereby controlling the cooling rate.
Ⅳ Our advantages
1. One-button automated process control. Can reach data acquisition, storage and printing.
2. Temperature circulation system :it made up of circulation fan ,wind plate ,and guide flow cover to improve heating transfer and circulation form into uniform temperature
3. Vacuum system :it made up of vacuum pump ,pipe ,vacuum gauge ,vacuum vale ,to supply composite material vacuum condition
4. Has fluid mechanics software to help users with simulation analysis.
5. Automatically control the pressure, the overpressure and over-temperature sound and light alarm is set on the auto-pressure tank
Contact Person: Lu